Digital Matter Eagle manual

1

.

Connecting sensor

Connect the supplied sensor correctly to the gateway.

  • Vs+ (white) → VOUT right of the module (right)
  • Vs- (brown) → 4-20mA 1 at the sensor input (left)

2

.

Activate batteries

Remove the strip to activate the batteries.

Once inserted, the LED next to the GPS antenna should blink briefly. If it does not, it means that the unit has not yet been reset. In that case, remove the batteries for about two minutes to drain any residual charge, then reinsert them.

3

.

Close housing

  1. Place the lid on the gateway and gently squeeze it closed. The foam in the lid will press against the batteries and hold them firmly in place if the unit is turned over
  2. Tighten the 6 screws evenly. On initial assembly, the screws may be quite stiff.

Be sure to place the cover correctly. The foam should lie over the batteries. If you screw the cover on incorrectly, you will damage the gateway.

4

.

Installation

To track an object you can mount the gateway on it with screws, bolts, cable ties or industrial adhesives.

Be careful when choosing a mounting point

  1. Reduce the chance of accidental crushing or detachment.
  2. Increase GPS and cellular reception by mounting the gateway in a good location. Also provide adequate ventilation.

If the gateway is used as a battery-powered device, reception is critical to its performance.

Do not place the gateway under a steel cover plate to avoid reception problems.

5

.

After installation

1. After installing the gateway and sensor in the tank, fill the tank completely. 

2. If no assets have yet been created in your project from the tank, do so first. You can also change the name of an existing asset, should this be necessary.

To visualize the newly installed tank, add it to an asset group.

Modify the metadata "Tank100pct" and enter the 4-20mA value here from when the tank was completely full.

Please note! The tank monitor sends its data every hour, wait until you are sure it is the highest value.

When you have customized your metadata you can use the path "tank_level," this path is percentage based

add assets, Asset groups , modify asset metadata, modify asset name

6

.

Replacing batteries

The following batteries are recommended: "SAFT LSH14".

When a 4-20mA sensor is connected to the gateway, Lithium Thionyl Chloride (LTC) batteries should be used. Not all LTC batteries are built the same. Spiral type batteries are preferred. Bobbin type batteries may not be able to provide enough peak current.

If you want to replace the batteries and open the housing, make sure the silicone seal is in good condition before closing the housing again.